top of page

Digilent

Analog Discovery Pro 3000 Series

Portable High Resolution Mixed Signal Oscilloscopes

Analog Inputs:

  • Used in the Oscilloscope, Network Analyzer, Spectrum Analyzer, Voltmeter, Impedance Analyzer, and Data Logger

  • ADP3450: Four analog input channels accessible via front panel BNC connectors

  • ADP3250: Two analog input channels accessible via front panel BNC connectors

  • Channel type: single ended

  • Analog bandwidth: 55+ MHz @ -3 dB

  • Noise limiting hardware bandwidth filter: 20 MHz

    • Can be enabled or disabled

  • 14-bit resolution (16-bit resolution with oversampling)

  • Input range ±25 V (±50 V diff)

  • Input protected to ±50 V

  • Max sampling rate:

    • 0.5 GS/s (with oversampling enabled)

    • 100 MS/s default

  • AC or DC coupling

  • Input buffer Size

    • 128 MS total in record mode

    • 32 k + samples per channel in repeated/shift/screen modes

  • Channel type: single-ended

Analog Outputs:

  • Used in the Waveform Generator, Impedance Analyzer, and Network Analyzer

  • Two arbitrary waveform generator channels, accessible via front panel BNC connectors

  • 14-bit Resolution

  • AC amplitude (max): ±5 V

  • Analog bandwidth: 15 MHz @ -3 dB

  • Maximum Sampling Rate: 125 MS/s


Digital Power Supply:

  • One Power supply with two access points

  • Voltage Range: 1.2 V to 3.3 V

  • Output Current: 300 mA


Digital Inputs and Outputs:

  • Used in the Logic Analyzer, Pattern Generator, Protocol Analyzer, and Digital I/O

  • Channels: 16

  • Input logic standard: LVCMOS (adjustable 1.2 V to 3.3 V, 5 V tolerant)

  • Output logic standard: LVCMOS (adjustable 1.2 V to 3.3 V, 8 mA)

  • Max sampling rate: 125 MS/s

  • Logic analyzer buffer memory:

    • 64 MS total in Record Mode

    • 32 k+ per channel in Repeated/Shift/Screen modes


Advanced Triggering:

  • Trigger sources: oscilloscope analog channels, function generator start, digital I/O lines, external triggers, manual trigger button

  • Trigger Modes

    • None, auto, manual (forced trigger), single

  • Analog Trigger

    • Edge, pulse, transition, condition, level, hysteresis, hold-off

  • Digital Trigger

    • Edge, level, pattern, glitch, protocol


Connectivity:

  • Device to computer: USB or Ethernet connection (in Linux or Standard Modes)

  • 4 High-speed USB 2.0 ports for peripheral connection (enabled in Linux mode)

    • Enabled for set and tested WiFi dongles (in Linux Mode)


Other:

  • Auxiliary Powered

  • Dimensions: 23.40 cm x 19.40 cm x 3.81 cm (9.2 in x 7.6 in x 1.5 in)

  • Weight: 450 g


Product Compliance: 

  • HTC: 8471809000

  • ECCN: 3A992.a

bottom of page